Reference
Duct bank spacer size chart.
Conduit OD, the hole we cut, and the overall plate size for common layouts. Bookmark it for the next takeoff.
Hole sizes
PVC Schedule 40 conduit OD and hole size
Every hole is cut at the conduit's outside diameter plus 1/8" clearance, so the pipe slides through without slop.
| Trade size | Conduit OD | Hole we cut | Hole (decimal) |
|---|---|---|---|
| 2" | 2.375" | ⌀ 2-1/2" | 2.500" |
| 2-1/2" | 2.875" | ⌀ 3" | 3.000" |
| 3" | 3.500" | ⌀ 3-5/8" | 3.625" |
| 3-1/2" | 4.000" | ⌀ 4-1/8" | 4.125" |
| 4" | 4.500" | ⌀ 4-5/8" | 4.625" |
| 5" | 5.563" | ⌀ 5-11/16" | 5.688" |
| 6" | 6.625" | ⌀ 6-3/4" | 6.750" |
OD values are nominal Schedule 40 PVC conduit sizes. If your project uses a different conduit type, send the spec and we cut to it.
Plate sizes
Overall spacer size for common layouts
4" conduit at 3" spacing between conduits. Base spacers include a 3" foot; intermediates do not. Layout is rows × conduits per row.
| Layout | Base spacer (W × H) | Intermediate (W × H) | Links |
|---|---|---|---|
| 1 × 2 | 15-1/4" × 10-5/8" | 15-1/4" × 7-5/8" | Sketch · Submittal |
| 2 × 2 | 15-1/4" × 18-1/4" | 15-1/4" × 15-1/4" | Sketch · Submittal |
| 2 × 3 | 22-7/8" × 18-1/4" | 22-7/8" × 15-1/4" | Sketch · Submittal |
| 3 × 3 | 22-7/8" × 25-7/8" | 22-7/8" × 22-7/8" | Sketch · Submittal |
| 3 × 4 | 30-1/2" × 25-7/8" | 30-1/2" × 22-7/8" | Sketch · Submittal |
| 4 × 4 | 30-1/2" × 33-1/2" | 30-1/2" × 30-1/2" | Sketch · Submittal |
| 2 × 6 | 45-3/4" × 18-1/4" | 45-3/4" × 15-1/4" | Sketch · Submittal |
Edge margin = half the spacing, never less than 1-1/2". Width = conduits per row × hole + spacing × (conduits per row − 1) + 2 × edge margin.
Calculator
Size any layout.
Pick a conduit, pattern and spacing. Open it in the layout builder to see the drawing, or pull a submittal sheet.
Notes
Before you order
- Spacing between conduits is per the engineer's duct bank detail for your project.
- The interval between spacers along the trench is set by the engineer or project spec. Send it with the trench length and we will work out the count.
- This chart is for planning. A final drawing is sent for your approval before anything is cut.
- Mixed conduit sizes in one bank are common. Send the detail and we lay out each hole.
How big is the hole for 4" PVC conduit?
Schedule 40 PVC 4" conduit has an outside diameter of 4.500". We cut the hole at the OD plus 1/8", so 4-5/8".
How is the overall spacer size worked out?
Width = conduits per row × hole + spacing between conduits × (conduits per row − 1) + two edge margins. Height is the same for rows, plus a 3" foot on base spacers. The edge margin is half the spacing, never less than 1-1/2".
What conduit spacing should I use?
Use the spacing on the engineer's duct bank detail for the project. The chart and calculator only do the geometry.
How far apart do spacers go along the trench?
The interval is set by the engineer or the project spec. Tell us the trench length and interval and we will work out the count.